Home Sitemap Contacts Media
MCS 657 - Technical Specification
CONTROL UNIT
  Power Supply - 60 to 140 VDC
  Power Consumption - 25W approx
  Number of Digital Inputs - 128 Nos, with LED indication on fascia
  Number of Digital Outputs - 80 Nos, with LED indication on fascia and with Overload and Short Circuit Protection
  Number of Analog Inputs - 5 Nos. provision for 8 Nos with LED indication on fascia
  Fault Log Memory - 3160 Faults with fault data packs with Date and Time stamp
  Communication - On RS 485 with display Units
  Fault Data Down Loading - Through USB port provided on Control unit
  I/O Couplers - Bayonet Connectors
  Dimensions -  305mm (H)x 385mm (W) x 765mm (L)
  Weight  - 55 Kgs
DISPLAY UNIT
  Power Supply - 60 to 140 VDC
  Power Consumption - 10W approx.
  LCD - 40 X 4 lines alphanumeric back lit provision
  I/O Couplers - Bayonet Connectors
  Notch Indicator - Two digit 7 segment Indication
  Back Lit - ON / OFF control
  Contrast - Adjustable through Keyboard
  Keyboard - 8 Keys of sealed membrane keyboard
  Dimensions -  50mm (H)x 150mm (W) x 230mm (L)
  Weight  - 2 Kgs approx
INTELLIGENT SIGNAL CONDITIONING UNIT
  Power Supply - 60 to 140 VDC
  Power Consumption - 10W approx
  I/O Couplers - Bayonet Connectors
  Number of TM Current Input - 3 Nos.
  Dimensions -  205mm (H)x 98mm (W) x 227mm (L)
  Weight  - 3 Kgs approx
SIGNAL CONDITIONING UNIT
  Power Supply - 18V DC from Control Unit
  Power Consumption - 10W approx
  I/O Coupler - Bayonet Connector
  Number of Analog voltage channels - 5 Nos
  Dimensions - 100mm (H) x 160mm (W) x 208 mm (L)
  Weight  - 3 Kgs approx
 

 

 

 