CONTROL UNIT |
| |
Power Supply - 60 to 140 VDC |
| |
Power Consumption - 25W approx |
| |
Number of Digital Inputs - 128 Nos, with LED indication on fascia |
| |
Number of Digital Outputs - 80 Nos, with LED indication on fascia and with Overload and Short Circuit Protection |
| |
Number of Analog Inputs - 5 Nos. provision for 8 Nos with LED indication on fascia |
| |
Fault Log Memory - 3160 Faults with fault data packs with Date and Time stamp |
| |
Communication - On RS 485 with display Units |
| |
Fault Data Down Loading - Through USB port provided on Control unit |
| |
I/O Couplers - Bayonet Connectors |
| |
Dimensions - 305mm (H)x 385mm (W) x 765mm (L) |
| |
Weight - 55 Kgs |
 |
DISPLAY UNIT |
| |
Power Supply - 60 to 140 VDC |
| |
Power Consumption - 10W approx. |
| |
LCD - 40 X 4 lines alphanumeric back lit provision |
| |
I/O Couplers - Bayonet Connectors |
| |
Notch Indicator - Two digit 7 segment Indication |
| |
Back Lit - ON / OFF control |
| |
Contrast - Adjustable through Keyboard |
| |
Keyboard - 8 Keys of sealed membrane keyboard |
| |
Dimensions - 50mm (H)x 150mm (W) x 230mm (L) |
| |
Weight - 2 Kgs approx |
 |
INTELLIGENT SIGNAL CONDITIONING UNIT
|
| |
Power Supply - 60 to 140 VDC |
| |
Power Consumption - 10W approx |
| |
I/O Couplers - Bayonet Connectors |
| |
Number of TM Current Input - 3 Nos. |
| |
Dimensions - 205mm (H)x 98mm (W) x 227mm (L) |
| |
Weight - 3 Kgs approx |
 |
SIGNAL CONDITIONING UNIT |
| |
Power Supply - 18V DC from Control Unit |
| |
Power Consumption - 10W approx |
| |
I/O Coupler - Bayonet Connector |
| |
Number of Analog voltage channels - 5 Nos |
| |
Dimensions - 100mm (H) x 160mm (W) x 208 mm (L) |
| |
Weight - 3 Kgs approx |