Contact Us Blog Forum Sitemap

Microprocessor Based Locomotive Control System (MEP 660) - Specifications
Power Supply
  50 to 90 VDC, 22V for 2 seconds
Digital Inputs
  80 inputs for interfacing 72VDC signals. Optically isolated, reverse polarity and surge protected.
Frequency Inputs
  6 input. for Traction Motor speed and 1 for Engine speed
Analog Inputs
  32 inputs Expandable to 40 inputs
Digital Outputs
  48 outputs for driving 72 V loads, expandable to 64 outputs.Optically isolated, reverse polarity, surge, overload and short circuit Protected
PWM Outputs
  2 outputs for Exciter Control and Auxiliary Generator Field Control
Fault Log Memory
  380 Faults with Date / Time Stamps and 8 Data Packs
Serial Communication Ports
  RS 485 Port for Display Unit, RS 232 Port for Fault Data Downloading, RS 232 Port for Configuration Upload, RS 485 Port for communication with MEG 601, RS 232 Port for Data Log and USB port for data log and event recorder data download
Display
  40 character x 4 lines Vacuum Fluorescent Display
Keyboard
  16 key membrane Keyboard
Interconnection
  Polarized MS Round Circular Threaded Connectors
Cooling
  Naturally cooled (no need for forced air cooling)
Protection
  EMI, EMC and ESD protection

 

 

  Privacy Statement | Terms Of Use | ©2007 MedhaIndia.Com